we have developed a series of utility routines to display and analyze atomic spectroscopy and lifetime data from our Low Energy Heavy Ion Accelerator... the macros work fine when called from the CINT command line via the .x command... they do NOT work fine when the .x command is assigned to a Control Bar Button and input from the keyboard is requested by the macro... input from a scanf command in the macro gets garbled in a fashion which is different in WinNT from what it is in Win95: in NT, the first character input gets stripped off and goes into a buffer, where CINT finds it after the macro has finished; in Win95, characters are intermittently and irreproducibly echoed to the keyboard- with the extraneous characters going into a buffer, where they appear after the macro has executed it would make the users' lives much simpler if the macros could be invoked from buttons rather than from the command line, and any suggestions you have would be most welcome... many thanks RM Schectman Professor of Physics University of Toledo
This archive was generated by hypermail 2b29 : Tue Jan 04 2000 - 00:43:36 MET